Model | Rated voltage | Operating voltage | Input current |
Voltage level | |
---|---|---|---|---|---|
Must operate voltage |
Must release voltage |
||||
G3TA-IAZR02S-US | 100 to 240 VAC | 80 to 264 VAC | 5 mA max. | 80 VAC max. | 10 VAC min. |
G3TA-IDZR02S-US | 5 to 24 VDC | 4 to 32 VDC | 4 VDC max. | 1 VDC min. | |
G3TA-IDZR02SM-US | 4 to 24 VDC | 3 to 32 VDC | 3 VDC max. |
Model | Logic level supply voltage |
Output breakdown voltage |
Output current | Output current (load current) |
VCEO (reference value) |
---|---|---|---|---|---|
G3TA-IAZR02S-US | 4 to 32 VDC | 32 VDC max. | 25 mA max. | 0.1 to 25 mA | 80 V |
G3TA-IDZR02S-US | |||||
G3TA-IDZR02SM-US |
Model | Rated voltage |
Operating voltage | Input impedance |
Voltage level | |
---|---|---|---|---|---|
Must operate voltage | Must release voltage |
||||
G3TA-OA202SZ-US | 12 VDC | 9.6 to 13.2 VDC | 0.9 kΩ±20% | 9.6 VDC max. | 2 VDC min. |
24 VDC | 19.2 to 26.4 VDC | 1.7 kΩ±20% | 19.2 VDC max. | ||
G3TA-OA202SL-US | 12 VDC | 9.6 to 13.2 VDC | 0.9 kΩ±20% | 9.6 VDC max. | |
24 VDC | 19.2 to 26.4 VDC | 1.7 kΩ±20% | 19.2 VDC max. | ||
G3TA-ODX02S-US | 12 VDC | 9.6 to 13.2 VDC | 3.5 kΩ±20% | 9.6 VDC max. | |
24 VDC | 19.2 to 26.4 VDC | 6.5 kΩ±20% | 19.2 VDC max. | ||
G3TA-OD201S-US | 12 VDC | 9.6 to 13.2 VDC | 3.6 kΩ±20% | 9.6 VDC max. | |
24 VDC | 19.2 to 26.4 VDC | 6.4 kΩ±20% | 19.2 VDC max. |
Model | Rated load voltage |
Load voltage range |
Load current (See note.) |
Inrush current | VDRM, VCEO (reference value) |
---|---|---|---|---|---|
G3TA-OA202SZ-US | 100 to 240 VAC | 75 to 264 VAC | 0.05 to 2 A | 30 A (60 Hz, 1 cycle) | 600 (VDRM) |
G3TA-OA202SL-US | 100 to 240 VAC | 75 to 264 VAC | |||
G3TA-ODX02S-US | 5 to 48 VDC | 4 to 60 VDC | 0.01 to 2 A | 12 A (10 ms) | 80 (VCEO) |
G3TA-OD201S-US | 48 to 200 VDC | 40 to 200 VDC | 0.01 to 1 A | 6 A (10 ms) | 400 (VCEO) |
Note: The minimum current value is measured at 10°C min.
Item | G3TA-IAZR02S-US | G3TA-IDZR02S-US | G3TA-IDZR02SM-US |
---|---|---|---|
Operate time | 20 ms max. | 0.5 ms max. | |
Release time | 20 ms max. | 0.5 ms max. | |
Output ON voltage drop | 1.6 V rms max. | 1.6 V max. | |
Leakage current | 5 μA max. | ||
Insulation resistance | 100 MΩ min. (at 500 VDC) | ||
Dielectric strength | 4,000 VAC, 50/60 Hz for 1 min between input and output | ||
Vibration resistance | Malfunction: 10 to 55 to 10 Hz, 0.75-mm single amplitude | ||
Shock resistance | Malfunction: 1,000 m/s2 | ||
Ambient temperature | Operating: -30°C to 80°C (with no icing or condensation) Storage: -30°C to 100°C (with no icing or condensation) |
||
Ambient humidity | Operating: 45% to 85% | ||
Certified standards | UL508 file No. E64562/CSA C22.2 (No. 0, No. 14) file No. LR35535 | ||
Weight | Approx. 16 g | ||
MTTFd (Reference value) | 1,000 years min. |
Certified standards | G3TA-OA202SZ-US | G3TA-OA202SL-US | G3TA-ODX02S-US | G3TA-OD201S-US |
---|---|---|---|---|
Operate time | 1/2 of load power source cycle + 1 ms max. |
1 ms max. | 0.5 ms max. | 2 ms max. |
Release time | 1/2 of load power source cycle + 1 ms max. |
2 ms max. | 2 ms max. | |
Output ON voltage drop |
1.6 V rms max. | 1.6 V max. | 2.5 V max. | |
Leakage current |
5 mA max. (at 200 VAC) | 1 mA max. | ||
Insulation resistance |
100 MΩ min. (at 500 VDC) | |||
Dielectric strength |
4,000 VAC, 50/60 Hz for 1 min between input and output | |||
Vibration resistance |
Malfunction: 10 to 55 to 10 Hz, 0.75-mm single amplitude | |||
Shock resistance |
Malfunction: 1,000 m/s2 | |||
Ambient temperature |
Operating: -30°C to 80°C (with no icing or condensation) Storage: -30°C to 100°C (with no icing or condensation) |
|||
Ambient humidity | Operating: 45% to 85% | |||
Certified standards | UL508 file No. E64562, CSA C22.2 (No. 14) file No. LR3553 | |||
Weight | Approx. 23 g | |||
MTTFd (Reference value) |
1,000 years min. |