Terminal Relay G6D-F4B OMRON

Price :
Contact
Quantity :
Status :
In Stock
Request a Quote
Share:
  • Product No
    4085
  • Brand
  • Origin
    JAPAN
  • Guarantee
    12 MONTHS
Model with Push-In Plus technology Added to Terminal Relays with Four-point Output Lineup
DO YOU NEED SUPPORT ?

Terminal Relay G6D-F4B OMRON

Ngan Anh Phat Co., Ltd specializes in providing genuine  products Terminal Relay G6D-F4B OMRON from the manufacturer Omron, originating from Japan, to the Vietnamese market.


Outstanding features of the Terminal Relay G6D-F4B OMRON:

• Realized 5 A rating by optimal designs for wide variety of applications (Push-In Plus technology).

• Push-In Plus terminal enables work reduction and requires no retightening.

• Short Bars (order separately) ensure easy common wiring and crossover wiring to adjacent terminal relays.

• Double wire method enables branch wiring (Push-In Plus technology)

• Each relay has independent coils and contacts for PLC output compatible (both NPN and PNP).

• Mechanical Relay models and power MOS FET relay models (for high frequency contact ratings) are available.

• LED operation indicator, diode for coil surge absorption, and tools for easy removal of relays are included as standard equipment.

• UL and CSA certification for standard models.
   VDE certification for Screws terminal, TÜV certification for Push-In Plus terminal.
   IP20 protection code for Push-In Plus models.

Specifications

Ratings

Relay Specification

Coil Ratings (per G6D Relay)

Operation
coil rating
Rated current
(mA)
Coil resistance
(Ω)
Must operate
voltage (V)
Must release
voltage (V)
Max.
voltage (V)
Power
consumption (mW)
DC 12 18.7 720 70%
max.*
10%
min.
130% Approx. 200
24 10.5 2,880

Note:
1. Rated current and coil resistance were measured at a coil temperature of 23°C with a tolerance of ±20%.
2. Performance characteristic data are measured at a coil temperature of 23°C.
3. The maximum allowable voltage is the maximum value of the operating voltage for the relay coil operating power supply. There is no continuous allowance.
4. The rated current includes the terminal’s LED current.
* The must operate voltage is 75% or less of the rated voltage if the relay is mounted in the upside down.

Contact Ratings (per G6D Relay)

G6D-F4PU (Model with Push-In Plus technology)

Load Resistive load (cosφ = 1)
Rated load 5 A at 250 VAC, 5 A at 30 VDC
Rated carry current 5 A
Max. switching voltage 250 VAC, 30 VDC
Max. switching current 5 A
Max. switching capacity (reference value) 1,250 VA, 150 W

 

G6D-F4B (Model with Screw terminal)

Load Resistive load (cosφ = 1)
Rated load 3 A at 250 VAC, 3 A at 30 VDC
Rated carry current * 5 A
Max. switching voltage 250 VAC, 30 VDC
Max. switching current * 5 A
Max. switching capacity (reference value) * 1,250 VA, 150 W

 

* The specifications become 3 A, 750 VA, and 90 W when all four outputs are powered at the same time.

Characteristics

Model G6D-F4PU
(Model with Push-In Plus technology)
Relay output
Contact resistance *1 100 mΩ max.
Operate time *2 10 ms max.
Release time *2 10 ms max.
Insulation resistance 1,000 MΩ min. (at 500 VDC)
Dielectric
strength
Between coil and
contacts
2,000 VAC, 50/60 Hz for 1 min
Between contacts
of the same polarity
750 VAC, 50/60 Hz for 1 min
Shock resistance voltage
(between coil and contacts)
4,000 V (1.2 × 50 μs)
Vibration re-
sistance
Destruction 10 to 55 to 10 Hz, 0.75-mm single amplitude
(1.5-mm double amplitude)
Malfunction 10 to 55 to 10 Hz, 0.75-mm single amplitude
(1.5-mm double amplitude)
Shock
resistance
Destruction 500 m/s2
Malfunction 100 m/s2
Endurance Mechanical 20,000,000 operations min.
(switching frequency: 18,000 operations/hr)
Electrical *2 70,000 operations min.
(5 A at 250 VAC, resistive load)
70,000 operations min.
(5 A at 30 VDC, resistive load)
(at 1,800 switching frequencies/hr)
Failure rate P Level
(reference value *3)
10 mA at 5 VDC
Ambient operating temperature,
Ambient storage temperature
-25 to 55°C (with no icing)
Ambient operating humidity 45% to 85%
LED color Yellow
Sealing IP20
Weight Approx. 86 g

 

Note: The data shown above are initial values.
*1. Measurement condition: 1 A at 5 VDC
*2. Ambient temperature condition: 23°C
*3. This value is measured at 120 switching frequencies/min.