Outstanding features of the LY Bi-power Relays OMRON:

• Wiring work can be shortened by as much as 60%* compared to conventional screw terminal sockets by combining with push-in plus terminal sockets (PTF-[]-PU) that feature light insertion force and strong pull-out strength to achieve less wiring work.

• The standard models include models that are compliant with the UL and CSA safety standards and with the Electrical Appliances and Material Safety Act.

• Equipped with an arc barrier for arc interruption.

• Withstand voltages up to 2,000 V.

• New built-in diode and built-in CR circuit models have joined the series.

• The lineup also includes models that are compliant with the LR and VDE safety standards.

* When both push-in plus terminals and screw terminal sockets are combined with plug-in terminal types (according to actual OMRON measurements as of November 2015)

 

Specifications

Standard Models with Built-in Operation Indicators

Operating Coil, Single-pole and Double-pole Models

Item Rated current
(mA)
Coil
resist-
ance
(Ω)
Coil inductance (H) Must-
operate
voltage
(V)
Must-
release
voltage
(V)
Maximum
voltage
(V)
Power
con-
sumption
(VA, W)
Rated
voltage (V)
50 Hz 60Hz Armature
OFF
Armature
ON
AC 12 106.5 91 46 0.17 0.33 80% max.
*1
30% min.
*2
110% of
rated
voltage
Approx. 1.0
to 1.2
(at 60 Hz)
24 53.8 46 180 0.69 1.3
50 25.7 22 788 3.22 5.66
100/110 11.7/12.9 10/11 3,750 14.54 24.6 Approx. 0.9
to 1.1
(at 60 Hz)
110/120 9.9/10.8 8.4/9.2 4,430 19.2 32.1
200/220 6.2/6.8 5.3/5.8 12,950 54.75 94.07
220/240 4.8/5.3 4.2/4.6 18,790 83.5 136.4
DC 6 150 40 0.16 0.33 10% min.
*2
Approx. 0.9
12 75 160 0.73 1.37
24 36.9 650 3.2 5.72
48 18.5 2,600 10.6 21.0
100/110 9.1/10 11,000 45.6 86.2

 

3 poles

Item Rated current
(mA)
Coil
resist-
ance
(Ω)
Coil inductance (H) Must-
operate
voltage
(V)
Must-
release
voltage
(V)
Maximum
voltage
(V)
Power
con-
sumption
(VA, W)
Rated
voltage (V)
50 Hz 60Hz Armature
OFF
Armature
ON
AC 12 159 134 24 0.12 0.21 80% max.
*1
30% min.
*2
110% of
rated
voltage
Approx.
1.6 to 2.0
(at 60 Hz)
24 80 67 100 0.44 0.79
100/110 14.1/16 12.4/13.7 2,300 10.5 18.5
200/220 9.0/10.0 7.7/8.5 8,650 34.8 59.5
DC 12 112 107 0.45 0.98 10% min.
*2
Approx. 1.4
24 58.6 410 1.89 3.87
48 28.2 1,700 8.53 13.9
100/110 12.7/13 8,500 29.6 54.3

 

4 poles

Item Rated current
(mA)
Coil
resist-
ance
(Ω)
Coil inductance (H) Must-
operate
voltage
(V)
Must-
release
voltage
(V)
Maximum
voltage
(V)
Power
con-
sumption
(VA, W)
Rated
voltage (V)
50 Hz 60Hz Armature
OFF
Armature
ON
AC 12 199 170 20 0.1 0.17 80% max.
*1
30% min.
*2
110% of
rated
voltage
Approx.
1.95 to 2.5
(at 60 Hz)
24 93.6 80 78 0.38 0.67
100/110 22.5/25.5 19/21.8 1,800 10.5 17.3
200/220 11.5/13.1 9.8/11.2 6,700 33.1 57.9
DC 12 120 100 0.39 0.84 10% min.
*2
Approx. 1.5
24 69 350 1.41 2.91
48 30 1,600 6.39 13.6
100/110 15/15.9 6,900 32.0 63.7

 

Refer to List of Certified Models for a list of models that are certified for safety standards and the Electrical Appliances and Material Safety Act.

Classification 1 pole Double-, 3-, and 4-pole
models
Bifurcated contacts
Load Resistive
load
Inductive load
(cos φ = 0.4,
L/R = 7 ms)
Resistive
load
Inductive load
(cos φ = 0.4,
L/R = 7 ms)
Resistive
load
Inductive load
(cos φ = 0.4,
L/R = 7 ms)
Contact type Single Bifurcated
Contact
materials
Ag alloy Ag
Rated load 15 A at 110 VAC
15 A at 24 VDC
10 A at 250 VAC 10 A at 110 VAC
7 A at 24 VDC
10 A at 110 VAC
10 A at 24 VDC
10 A at 250 VAC 7.5 A at 110 VAC
5 A at 24 VDC
5 A at 24 VDC
5 A at 110 VAC
5 A at 24 VDC
4 A at 110 VAC
4 A at 24 VDC
Electrical endurance*1 200,000
operations min.
200,000
operations min.
200,000
operations min.
3-, 4-pole: 200,000 operations min.
2-pole: 500,000 operations min.
50,000
operations min.
3-, 4-pole: 200,000 operations min.
2-pole: 500,000 operations min.
2-pole: 500,000 operations min.
Rated carry
current
15 A 10 A 7 A
Maximum
contact
voltage
250 VAC
125 VDC
250 VAC
125 VDC
250 VAC
125 VDC
Maximum
contact
current
15 A 10 A 7 A

 

 

Type Single-pole and double-pole models
(standard models and bifurcated
contact models)
Single-pole, double-pole models
(models with built-in operation indicators,
models with built-in diodes, and models with
built-in CR circuits),
3-pole and 4-pole models
Ambient operating
temperature
-25 to 55°C
(with no icing or condensation) *2
-25 to +40°C
(with no icing or condensation) *3
Ambient operating
humidity
5% to 85%

 

Characteristics

Type Standard models, models with
built-in operation indicators,
models with built-in CR circuits,
and models with built-in diodes
Bifurcated contacts
Contact resistance *1 50 mΩ max.
Operating time *2 25 ms max.
Release time *2 25 ms max.
Maximum
operating
frequency
Mechanical 18,000 operations/h
Rated load 1,800 operations/h
Insulation resistance *3 100 MΩ min.
Dielectric
strength
Between coil and
contacts
2,000 VAC at 50/60 Hz for 1 min.
Between contacts
of different
polarity
Between contacts
of the same
polarity
1,000 VAC at 50/60 Hz for 1 min.
Vibration
resistance
Destruction 10 to 55 to 10 Hz, 0.5-mm single amplitude (1.0-mm double amplitude)
Malfunction 10 to 55 to 10 Hz, 0.5-mm single amplitude (1.0-mm double amplitude)
Shock
resistance
Destruction 1,000 m/s2
Malfunction 200 m/s2
Endurance Mechanical AC: 50,000,000 operations min.
DC: 100,000,000 operations min.
(switching frequency: 18,000 operations/h)
Failure rate P value
(reference value) *4
100 mA at 5 VDC 10mA at 5 VDC
Weight 1-pole and 2-pole: 40 g, 3-pole: Approx. 50 g, 4-pole: Approx. 70 g