Cylindrical Proximity Sensor E2B Series

Price :
Contact
Quantity :
Status :
In Stock
Request a Quote
Share:
  • Product No
    3418
  • Brand
  • Guarantee
    12 THÁNG
DO YOU NEED SUPPORT ?

Cylindrical Proximity Sensor E2B Series

NGAN ANH PHAT CO.,LTD chuyên cung cấp dòng sản phẩm Cylindrical Proximity Sensor E2B Series chính hãng từ nhà sản xuât Omron xuất xứ Japan tại thị trường Việt Nam.

DimensionsKICH_THUOC_CAM_BIEN_TIEM_CAN_E2B_SERIES

Size M8
Sensing distance Single Double
Type Shielded Unshielded Shielded Unshielded
Model E2B-S08[]S01 E2B-S08[]N02 E2B-S08[]S02 E2B-S08[]N04
Sensing distance 1.5 mm ± 10% 2 mm ± 10% 2 mm ± 10% 4 mm ± 10%
Setting distance 0 to 1.2 mm 0 to 1.6 mm 0 to 1.6 mm 0 to 3.2 mm
Differential travel 10% max. of sensing distance
Detectable object Ferrous metal (The sensing distance decreases with non-ferrous metal.)
Standard sensing object 
(mild steel ST37)
8 × 8 × 1 mm 8 × 8 × 1 mm 8 × 8 × 1 mm 12 × 12 × 1 mm
Response frequency *1 2,000 Hz 1,000 Hz 1,500 Hz 1,000 Hz
Power supply voltage 10 to 30 VDC. (including 10% ripple (p-p))
Current consumption 10 mA max.
Output type -B models: PNP open collector 
-C models: NPN open collector
Control 
output
Load current *2 200 mA max. (30 VDC max.)
Residual voltage 2 V max. (under load current of 200 mA with cable length of 2 m)
Indicator Operation indicator (Yellow LED)
Operation mode (with sensing 
object approaching)
-B1/-C1 models: NO 
-B2/-C2 models: NC
Protection circuit Output reverse polarity protection, Power source circuit reverse polarity protection, 
Surge suppressor, Short-circuit protection
Ambient air temperature Operation and storage: -25 to 70°C (with no icing or condensation)
Temperature influence *2 ±10% max. of sensing distance at 23°C within temperature range of -10 to 55°C 
±15% max. of sensing distance at 23°C within temperature range of -25 to 70°C
Ambient humidity Operation and Storage: 35 to 95%
Voltage influence ±1% max. of sensing distance in 24 VDC ±15%
Insulation resistance 50 MΩ min. (at 500 VDC) between current-carrying parts and case
Dielectric strength 1,000 VAC at 50/60 Hz for 1 min between current-carrying parts and case
Vibration resistance 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y and Z directions
Shock resistance 500 m/s2 , 10 times each in X, Y and Z directions
Standard and listings (1) IP67 (IEC60529) (2) EMC (EN60947-5-2)
Connecting method Pre-wired models (standard is 4 mm dia. PVC cable with length = 2 m, 5 m). 
Connector models (M8-3pin)
Weight 
(packaged)
Pre-wired model Short body: Approx. 65 g, Long body: Approx. 65 g
Connector model Short body: Approx. 20 g, Long body: Approx. 20 g
Material Case Stainless steel (1.4305 (W.-No.), SUS 303 (AISI), 2346 (SS).)
Sensing surface PBT
Cable Standard cable is 4 mm dia. PVC.
Clamping nut Brass-nickel plated
Toothed washer Zinc-plated iron

 

Size M12
Sensing distance Single Double
Type Shielded Unshielded Shielded Unshielded
Model E2B-M12[]S02 E2B-M12[]N05 E2B-M12[]S04 E2B-M12[]N08
Sensing distance 2 mm ± 10% 5 mm ± 10% 4 mm ± 10% 8 mm ± 10%
Setting distance 0 to 1.6 mm 0 to 4 mm 0 to 3.2 mm 0 to 6.4 mm
Differential travel 10% max. of sensing distance
Detectable object Ferrous metal (The sensing distance decreases with non-ferrous metal.)
Standard sensing object 
(mild steel ST37)
12 × 12 × 1 mm 15 × 15 × 1 mm 12 × 12 × 1 mm 24 × 24 × 1 mm
Response frequency *1 1,500 Hz 800 Hz 1,000 Hz 800 Hz
Power supply voltage 10 to 30 VDC. (including 10% ripple (p-p))
Current consumption 10 mA max.
Output type -B models: PNP open collector 
-C models: NPN open collector
Control 
output
Load current 200 mA max. (30 VDC max.)
Residual voltage 2 V max. (under load current of 200 mA with cable length of 2 m)
Indicator Operation indicator (Yellow LED)
Operation mode (with sensing 
object approaching)
-B1/-C1 models: NO 
-B2/-C2 models: NC
Protection circuit Output reverse polarity protection, Power source circuit reverse polarity protection, 
Surge suppressor, Short-circuit protection
Ambient air temperature Operation and storage: -25 to 70°C (with no icing or condensation)
Temperature influence ±10% max. of sensing distance at 23°C within temperature range of -10 to 55°C 
±15% max. of sensing distance at 23°C within temperature range of -25 to 70°C
Ambient humidity Operation and Storage: 35 to 95%
Voltage influence ±1% max. of sensing distance in 24 VDC ±15%
Insulation resistance 50 MΩ min. (at 500 VDC) between current-carrying parts and case
Dielectric strength 1,000 VAC at 50/60 Hz for 1 min between current-carrying parts and case
Vibration resistance 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y and Z directions
Shock resistance 1,000 m/s2 , 10 times each in X, Y and Z directions
Standard and listings (1) IP67 (IEC60529) (2) EMC (EN60947-5-2)
Connecting method Pre-wired models (standard is 4 mm dia. PVC cable with length = 2 m, 5 m). 
Connector models (M12-4pin)
Weight 
(packaged)
Pre-wired model Short body: Approx. 75 g, Long body: Approx. 80 g *2
Connector model Short body: Approx. 35 g, Long body: Approx. 40 g
Material Case Brass-nickel plated
Sensing surface PBT
Cable Standard cable is 4 mm dia. PVC.
Clamping nut Brass-nickel plated
Toothed washer Zinc-plated iron

 

Size M18
Sensing distance Single Double
Type Shielded Unshielded Shielded Unshielded
Model E2B-M18[]S05 E2B-M18[]N10 E2B-M18[]S08 E2B-M18[]N16
Sensing distance 5 mm ± 10% 10 mm ± 10% 8 mm ± 10% 16 mm ± 10%
Setting distance 0 to 4 mm 0 to 8 mm 0 to 6.4 mm 0 to 12.8 mm
Differential travel 10% max. of sensing distance
Detectable object Ferrous metal (The sensing distance decreases with non-ferrous metal.)
Standard sensing object 
(mild steel ST37)
18 × 18 × 1 mm 30 × 30 × 1 mm 24 × 24 × 1 mm 48 × 48 × 1 mm
Response frequency *1 600 Hz 400 Hz 500 Hz 400 Hz
Power supply voltage 10 to 30 VDC. (including 10% ripple (p-p))
Current consumption 10 mA max.
Output type -B models: PNP open collector 
-C models: NPN open collector
Control 
output
Load current 200 mA max. (30 VDC max.)
Residual voltage 2 V max. (under load current of 200 mA with cable length of 2 m)
Indicator Operation indicator (Yellow LED)
Operation mode (with sensing 
object approaching)
-B1/-C1 models: NO 
-B2/-C2 models: NC
Protection circuit Output reverse polarity protection, Power source circuit reverse polarity protection, 
Surge suppressor, Short-circuit protection
Ambient air temperature Operation and storage: -25 to 70°C (with no icing or condensation)
Temperature influence ±10% max. of sensing distance at 23°C within temperature range of -10 to 55°C 
±15% max. of sensing distance at 23°C within temperature range of -25 to 70°C
Ambient humidity Operation and Storage: 35 to 95%
Voltage influence ±1% max. of sensing distance in 24 VDC ±15%
Insulation resistance 50 MΩ min. (at 500 VDC) between current-carrying parts and case
Dielectric strength 1,000 VAC at 50/60 Hz for 1 min between current-carrying parts and case
Vibration resistance 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y and Z directions
Shock resistance 1,000 m/s2 , 10 times each in X, Y and Z directions
Standard and listings (1) IP67 (IEC60529) (2) EMC (EN60947-5-2)
Connecting method Pre-wired models (standard is 4 mm dia. PVC cable with length = 2 m, 5 m). 
Connector models (M12-4pin)
Weight 
(packaged)
Pre-wired model Short body: Approx. 95 g, Long body: Approx. 110 g *2
Connector model Short body: Approx. 60 g, Long body: Approx. 80 g
Material Case Brass-nickel plated
Sensing surface PBT
Cable Standard cable is 4 mm dia. PVC.
Clamping nut Brass-nickel plated
Toothed washer Zinc-plated iron

 

Size M30
Sensing distance Single Double
Type Shielded Unshielded Shielded Unshielded
Model E2B-M30[]S10 E2B-M30[]N20 E2B-M30[]S15 E2B-M30[]N30
Sensing distance 10 mm ± 10% 20 mm ± 10% 15 mm ± 10% 30 mm ± 10%
Setting distance 0 to 8 mm 0 to 16 mm 0 to 11.25 mm 0 to 22.5 mm
Differential travel 10% max. of sensing distance
Detectable object Ferrous metal (The sensing distance decreases with non-ferrous metal.)
Standard sensing object 
(mild steel ST37)
30 × 30 × 1 mm 60 × 60 × 1 mm 45 × 45 × 1 mm 90 × 90 × 1 mm
Response frequency *1 400 Hz 100 Hz 250 Hz 100 Hz
Power supply voltage 10 to 30 VDC. (including 10% ripple (p-p))
Current consumption 10 mA max.
Output type -B models: PNP open collector 
-C models: NPN open collector
Control 
output
Load current 200 mA max. (30 VDC max.)
Residual voltage 2 V max. (under load current of 200 mA with cable length of 2 m)
Indicator Operation indicator (Yellow LED)
Operation mode (with sensing 
object approaching)
-B1/-C1 models: NO 
-B2/-C2 models: NC
Protection circuit Output reverse polarity protection, Power source circuit reverse polarity protection, 
Surge suppressor, Short-circuit protection
Ambient air temperature Operation and storage: -25 to 70°C (with no icing or condensation)
Temperature influence ±10% max. of sensing distance at 23°C within temperature range of -10 to 55°C 
±15% max. of sensing distance at 23°C within temperature range of -25 to 70°C
Ambient humidity Operation and Storage: 35 to 95%
Voltage influence ±1% max. of sensing distance in 24 VDC ±15%
Insulation resistance 50 MΩ min. (at 500 VDC) between current-carrying parts and case
Dielectric strength 1,000 VAC at 50/60 Hz for 1 min between current-carrying parts and case
Vibration resistance 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y and Z directions
Shock resistance 1,000 m/s2 , 10 times each in X, Y and Z directions
Standard and listings (1) IP67 (IEC60529) (2) EMC (EN60947-5-2)
Connecting method Pre-wired models (standard is 4 mm dia. PVC cable with length = 2 m, 5 m). 
Connector models (M12-4pin)
Weight 
(packaged)
Pre-wired model Short body: Approx. 160 g, Long body: Approx. 210 g *2
Connector model Short body: Approx. 140 g, Long body: Approx. 160 g
Material Case Brass-nickel plated
Sensing surface PBT
Cable Standard cable is 4 mm dia. PVC.
Clamping nut Brass-nickel plated
Toothed washer Zinc-plated iron